Sequentially confirmed activationThis requires two independent detectors to activate within 30 to 60minutes. The 30 to 60 minutes will be programmed at the control unit. For installation of movement detectors providing sequential confirmation the following applies:
Examples of permitted overlapping configurations:
Examples of sequential configuration:
An alarm condition from the first detector should generate an unconfirmed activation. If there is a subsequent alarm within the confirmation time then an unambiguous sequentially confirmed activation should be signalled. If a separate detector does not activate within the confirmation time the system should reinstate automatically. Following the activation of the first detector, if a second (confirmed) detector does not activate within the confirmation period the following applies:
|
|